Introduction
A veterinary ointment is judged by its texture, its stability and its behavior in the tube.These properties are decided before filling: in emulsification, in deaeration and in transfer.If brewing leaves air or thick drops, filling cannot correct it.
This article describes the brewing chain and the control points that connect the mixer to the filler.It is aimed at process managers who need the ointment to reach the tube in the expected conditions.

*Vacuum emulsifying tank with agitator and thermal jacket.*
The preparation chain
Thechain includes phase dosing, heating, emulsification, homogenization, deaeration, cooling and transfer.
Each stage has a parameter and a criterion.If one is skipped or run out of range, the texture changes.
The chain must be documented as part of the process.
Emulsification
Emulsification disperses one phase into another.Speed, time and temperature determine drop size and stability.
A poorly formed emulsion separates during storage or filling.
The emulsification criterion can be visual, microscopic orviscosity.
Homogenization
Homogenization reduces droplet size and improves stability.It can also incorporate air if the head is not submerged.
The order of operations matters: homogenizing before or after deaeration changes the result.
Power and time must be defined and recorded.

*Homogenization head immersed in the ointment.*
Deaeration
Deaeration eliminates incorporated air.It is done under vacuum, with slow stirring and sufficient time.
If the ointment retains air, the tube fills with bubbles and the weight varies.
The vacuum must be applied without causing boiling or dragging of the product.
Transfer
The transfer takes the ointment from the mixer tothe filling hopper.It can be by pump or by pressure.
The pump must handle high viscosity without excessive shear or incorporating air.
The pipe must be short and with as few elbows as possible.
Table ofstages
| Stage | Target | Parameter | Criteria | Risk |
|---|---|---|---|---|
| Dosage | Proportionof phases | Weight | Accuracy | Deviation offormula |
| Heating | Fluidity | Temperature | Range | Degradation |
| Emulsification | Dispersion | Velocityand time | Size ofdrop | Separation |
| Homogenization | Stability | Power | Repeatability | Airbuilt-in |
| Deaeration | Remove air | Vacuum and time | Nobubbles | Boiling |
| Transfer | Reach hopper | Pressure | Noair | Shear |
Relationship with filling
The ointment that reaches the hopper must have the expected viscosity and temperature.If it arrives cold or aerated, the dosage varies.
The hopper must maintain the temperature and prevent sedimentation.
Filling and preparation are a single process: separating them complicates the investigation of defects.
How the temperature in the tank is controlled
The temperature is controlled fromthe shirt and is confirmed on the product.The jacket delivers or removes heat through the wall, and the agitator must renew the mass that is in contact with that wall.If agitation is insufficient, the reading may stabilize while the rest of the product maintains a different temperature.That is why the control combines the setpoint of the service fluid with a representative reading of the product and with a clear idea of how the tank behaves in each phase.
The position of the sensor matters as much as its calibration.A sensor located next to the wall or at the bottom measures the area that changes first and not the average mass.It is advisable to define a reading point that represents the product, wait for the temperature to stabilize and repeat the reading before considering the stage completed.In large tanks, a single reading may not be sufficient, and the criteria should explain how a representative sample is obtained.It is also advisable to note the temperature of the service fluid and the time that the product remained at each level, because these data explain readings that deviate from what was expected.
The ramps are controlled in the same way as the final value.Heating too quickly creates internal differences and exposes sensitive components to unnecessary stress;Sudden cooling changes the viscosity prematurely and complicates the transfer.The rate of change is defined by formulation and is respected like any other parameter of the stage.
The acceptance criterion is a range and not an isolated value.If the temperature is left out, the step is stopped and evaluated before continuing, because subsequent emulsification and filling depend on that condition.King Pack can review the thermal configuration of the tank, propose reading points and recording appropriate to the product, and confirm in writing the scope of that review.
How the emulsion is verified
The emulsion is verified against a defined criterion before starting.It is not enough for the mixture to look good: the criterion can be based on observation of the surface, on the resistance that a sample presents when spread or on a laboratory measurement.The important thing is that the criterion is the same between batches and between operators, so that the comparison makes sense and does not depend on the impression of each shift.
In-process observation looks for signs of separation.Uneven gloss, visible droplets, a distinct film on the surface, or a deposit on the edge of the tank indicate that the dispersion is not stable.A sample taken with a spatula and spread on a plate allows you to see if the color and texture are uniform and if areas appear more fluid than others.
Instrumental verification may include viscosity or microscopic examination.Microscopy shows droplet size and distribution;Viscosity indicates whether the structure is maintained and whether the product responds as the reference.Both readings are compared to a product pattern and not a general expectation.
If the criterion is not met, deaeration is not continued as if the problem would resolve itself.Speed, time and temperature are reviewed, and it is decided if the stage is repeated or if the batch is segregated.The result of the verification is recorded together with the decision made, so that the next preparation is based on concrete information.Verification also has a repeatability component: two samples of the same mass must behave in a similar way when spread, and if one separates and the other does not, the problem is in the agitation or at the point of collection.
What to do if the ointment becomes aerated
When the ointment remains aerated, the first step is to confirm it.Bubbles can be seen on the surface or in a spread sample, and also manifest as a spongy texture, a matte appearance, and weight variation during filling.The observation must be made with the ointment at rest, because agitation disguises the air and redistributes it.
The usual causes are in the entry of air and not in the formula.A non-submerged head, air-entraining seals or connections, insufficient vacuum, and vortex-forming agitation draw air from the surface into the product.Air can also enter through the pipe if the transfer is made with the line empty or with poorly adjusted joints.
The correction is made in the tank.The vacuum is maintained with slow agitation for the necessary time, the product is allowed to rest and the tightness is checked before repeating the deaeration.It is not advisable to compensate for the problem by increasing the transfer pressure or adjusting the formula, because the air is still present and filling reveals it.
After correcting, it is decided whether the batch will continue, be reprocessed or segregated, according to the criteria defined for the product.The cause and action are recorded so that the setting is not lost.Rest helps because the air rises and concentrates near the surface, where the vacuum acts more easily;If bubbles persist after deaeration again, the cause is usually an active air intake and not the vacuum time.King Pack can review the deaeration stage and propose the configuration that corresponds to the product and tank type.
How to clean the tank between products
Cleaning between products is part of the change and is not an afterthought.Residues from one formula can be dragged into the next, alter the color, modify the texture or remain in areas that the rinse cannot reach.A poorly closed product change turns a correct batch into a batch with a deviation that is difficult to explain.
The sequence must be defined: emptying the product, rinsing, detergent compatible with the materials, final rinsing and drying.Cleaning includes the head, valves, tubing, tank bottom, walls and agitator surfaces.Also the dead zones, where the product accumulates and the cleaning flow does not arrive with the same intensity.
Verification combines visual inspection with the review of the final rinse, according to a criterion agreed in advance.The result is documented with the date, the previous product and the person performing the cleaning.If the criterion is not met, the next preparation is not started: the cleaning is repeated or the uncovered spot is investigated.
Compatibility of materials and waste management are also part of the procedure.It is advisable to check the condition of the joints and surfaces, because a worn joint or a scratch retains product and makes the cleaning appear correct without being so;This review is done before closing the change.King Pack can propose the cleaning sequence, indicate the inspection points and document the criteria agreed with each product, and confirm in writing the scope of that proposal.
What to document the preparation
The preparation record is what allows the batch to be repeated and a deviation explained.Without registration, the texture depends on the operator's memory and each batch becomes a different version of the previous one.Documenting is not a procedure: it is the way for the process to have a stable reference.
The identification of the batch and the phases, the dosed weights, the temperatures reached, the times, the speeds, the vacuum level and the order of operations are documented.Also the incidents, the corrections and the moment in which they were applied.When a stage is repeated, the log must show the repetition and not just the final result.
The log must indicate who executes and who reviews, and how the data is corrected when there is an error.Traceability requires that the record corresponds to that specific batch and not to a generic template copied from another preparation.An ambiguous data in the record becomes a doubt in the investigation.
With this data, defects are investigated, batches are compared and new personnel are trained.Trends that are not seen in a single batch are also detected.The record gains value when it can be read quickly: a sequence of fields in the order in which the process occurs is reviewed better than an unordered list, and someone investigating a defect should find the suspicious stage without going through the entire document.King Pack can document the recording sequence, propose which fields should be retained, and confirm in writing the scope of that documentation for each product.
How to correct a deviation during preparation
A deviation is a parameter outside the expected range or a criterion that is not met.It may appear in the temperature, in the emulsification time, in the vacuum level or in the appearance of the product.Not all of them have the same weight: some are corrected in the next stage and others require you to stop the preparation and evaluate the dough before continuing.
The first decision is whether the process continues.If the deviation affects a condition that later stages cannot correct, the preparation stops.If the stage can be repeated without damaging the product, it is repeated with the planned parameters and a record of the repetition is recorded, because the batch was not prepared in the same way as the previous one.
What should be avoided is compensating on the fly with adjustments that are not foreseen: increasing the speed, lengthening the vacuum without criteria or adding a component to recover the texture.These adjustments introduce variability and leave the batch without a clear explanation of what happened, just when it is most needed to understand.
When closing the deviation, the cause, action and result are recorded, and it is decided whether the batch follows the normal course or requires additional review.The deviation is closed when the cause is identified and the action is recorded, not when the product appears correct again.King Pack can review the treatment of deviations and propose the control points that should be documented, and confirm in writing the scope of this review.
Common errors
- Homogenize without submerging the head. Air is incorporated.
- Deaerate for a short time. Bubbles remain.
- Transfer with an inadequate pump. The product is sheared.
- Do not control the temperature.viscosity changes.
- Do not register parameters. Texture cannot be reproduced.
- Separate preparation and filling. The cause of the defect is looked for in the wrong place.
How King Pack supports
King Pack can review the preparation chain and propose the configuration ofproper mixing, deaeration and transfer to product.The scope includes the definition of parameters and training of personnel.Capacities and limits are confirmed in writing for each formulation.
Frequently Asked Questions
Can an ointment be filled without deaerating? You can, but the tube will have bubbles and the weight will be variable.
What vacuum is needed? Depends on the product and equipment.It is defined in the test.
Does the transfer change the texture? It can change it if the pump shears or incorporates air.
How long can the ointment wait in the hopper? It depends on the stability.It must be defined and respected.
Should the temperature of the hopper be controlled? Yes, if the ointment is sensitive.It affects the dosage.
How is deaeration verified? By density or visual inspection of a sample.
Can the same mixer be used for several products? With validated cleaning and own parameters per product.
Technical resourcesrelated
For further specification, please review high viscosity syringe filling and capping line and guide on high viscosity syringe fillingviscosity.These resources help refine samples, scope, and acceptance criteria before requesting a proposal.

*Deaeration of ointment under vacuum in the tank.*
Conclusion
Preparing an ointmentveterinary medicine is a chain: emulsify, homogenize, deaerate and transfer.Each stage has parameters and criteria, and filling depends on the chain arriving complete.
CTA