Reliable Filling Solutions for a Healthier World

Technical Guide

Filling of veterinary spot-on liquids: from mixing and filtration to feeding the filler

Spot-on process chain: mixing, filtration, transfer and feeding the filler, with control points that affect the dose.

Chain diagramprocess of a spot-on liquid

Introduction

A spot-on liquid reaches the filler after going through a chain: mixing, filtration, transfer and feeding.Each stage can alter what the filler receives.A poorly homogenized mixture, a filter that retains active ingredient or a transfer that incorporates air produce doses out of range even if the machine is adjusted.

This article describes the complete chain and the control points that determine the quality of the filling.It is aimed at process and quality managers who need the dose to be reproducible, not just that the machine works.

Diagram of the process chain of a spot-on liquid

*Mixing, filtration, transfer and filling chain of a spot-on.*

Why the chain matters more than themachine

The filler doses what it receives.If the product arrives with a different viscosity, with separated solids or with air, the dose varies even if the equipment maintains the same valve time.

Dose problems are often investigated at the nozzle, when the origin is in the mixing or transfer.Reviewing the entire chain saves time and avoids unnecessary machine changes.

Traceability of the chain—mixing batch, filter, transfer time—is part of the batch record.

The mixing

The mixing must produce a homogeneous and stable solution or suspension during the filling time.Stirring, temperature and order of addition determine the result.

If the product is an emulsion, the speed and time of stirring influence the droplet size and stability.A poorly formed emulsion separates during filling.

The mixing record should include parameters and verification of homogeneity.Without that record, dose variability cannot be explained.

Filtration

Filtration removes particles and protects the nozzle and the product.But the filter can also retain active ingredient if the pore size is not adequate.

The filter must be chosen carefully: pore, material and compatibility with the product.A filter that is too fine becomes clogged and changes the flow rate;one that is too thick allows particles to pass through that clog the nozzle.

The differential pressure indicates the state of the filter.An increase in pressure with the same flow rate suggests obstruction;a sudden drop may indicate breakage.

Stainless steel tank with agitator and temperature jacket

*Mixing tank with agitation and temperature control.*

The transfer

The transfer takes the product from the mixture to the filler.It can be by gravity, by pump or by gas pressure.Each option has a different effect on the product.

A centrifugal pump can shear and aerate;A positive displacement pump takes better care of the product, but requires pressure control.Gravity is gentle, but depends on the height and the route.

Air is incorporated in the transfer if the pipe is not purged or if the pump sucks from the surface.The air reaches the filler and appears as a bubble in the unit.

The filler feed

The filler receives the product in a hopper or in a pressurized circuit.The stability of the feed determines the repeatability of the dose.

If the hopper is emptied and refilled, the level changes and the pressure in the nozzle varies.If the circuit has pulsations, the dose oscillates.

The supply must be stabilized with a controlled level, a recirculation pump or an accumulator.The solution depends on the product and the flow rate.

Table of points ofcontrol

StageRiskControlRegistration
MixtureSeparation or emulsionunstableAgitation and temperatureMixing parameters
FiltrationActive retention or cloggingPorosity and pressuredifferentialFilter change
TransferAir or shearPurge and pump typeTime andpressure
FeedingLevel and pulsationsControlled level and recirculationLevel and flow
FillingDosevariableWeight and profileDose per batch

How the chain is verified

Verification begins in the mixture: sample at different heights and comparison.Still in the filter: differential pressure and flow.Continues in the transfer: purging and absence of air.And it ends in filling: dose by weighing.

If the dose varies, the chain is run in reverse order: first filling, then feeding, then transferring, then mixing.This order avoids changing the nozzle when the problem is in the hopper.

Material compatibility with the spot-on

The spot-on contains solvents, surfactants and active ingredients that can attack joints, hoses, diaphragms and coatings.Compatibility is assessed with the real product, not with a generic family: a material that swells releases particles, changes the volume of the conduction and shifts the dose over the weeks.

There are two planes that should be separated.Chemical resistance describes whether the material retains its properties during contact and stops.Inertness describes whether it transfers substances to the product or absorbs components of the formulation.In a spot-on, with small volumes and high concentrations, a minimum release weighs more than in a very diluted product, because the concentration range is narrow.

The test is static and with the real formulation: test pieces of the material submerged during the expected contact period, with control of weight, color, hardness and appearance.The test is documented and repeated if the formula or part supplier changes.King Pack can review the list of materials in contact and propose alternatives;the scope is confirmed in writing.

Temperature control in the transfer

The temperature changes the viscosity and, with it, the flow rate received by the filler.A cold product circulates thicker and takes longer to fill the valve;a hot one flows easily and can advance the dosage.If the transfer does not control the temperature, the filler doses a product different from the one that was verified in the mixture.

Heat also acts on the formulation.In emulsions, a high temperature accelerates phase separation and droplet growth;in suspensions, it favors sedimentation or reagglomeration.The effect is not always visible on the line: it appears as a dose variation between the beginning and the end of the course.

The control is based on three elements: measurement at the point of use, isolation of the pipes and a defined time margin between mixing and filling.It is advisable to record the temperature at the beginning, during and at the end of the transfer.King Pack can review the layout and propose measurement points, and documents the agreed criteria in writing, along with the reading frequency during the batch.

Cleaning the circuit between products

Changing products requires more than just a rinse.The remains of the previous formulation remain in valves, elbows, filters and dead sections, and are mixed with the next batch.In a spot-on, where the active ingredient is concentrated, a small residue can take the dose out of range in the first units.

The design of the circuit determines the cleaning.A route without blind sections, with a slope and with drainage valves, is cleaned sooner and with less liquid.Difficult spots are usually the filter, pump and nozzle, where product builds up and dries out.Manual cleaning depends on these points being accessible without disassembling half of the installation.

Cleaning is verified, not assumed: final rinse with clear liquid, visual check of the accessible surfaces and, when the case requires it, analysis of the last rinse.Acceptance criteria and washing order are documented per product.King Pack can review the circuit design and propose the cleaning sequence, and confirms in writing the points it covers.

Dose verification in pipettes

The dose of a spot-on pipette is verified by weighing, not by nominal volume.The weight of the filled unit, minus the weight of the empty pipette, gives the actual amount of product.The method requires controlling product temperature and evaporation, especially in small volumes.That is why the scale is verified before the batch and the reading is recorded.

The verification must cover the start, the center and the end of the batch, and also the pipettes at the ends of the filling line.The first unit after an adjustment or stop is usually the most deviated.Comparing only the average hides the dispersion that the customer perceives.

In addition to the weight, it is worth checking the appearance: filling without bubbles, closing without burrs and absence of product in the neck.These defects anticipate rejections even if the weight is in range.Acceptance limits are set with the product and documented;King Pack can review the sampling plan and propose control points, and confirms the scope in writing.

Waste and product recovery

Each batch leaves product in the tank, in the filter, in the pipes and in the machine itself.This residual volume has two consequences: it reduces performance and, if it is recovered without criteria, it returns to the circuit a product that has already been exposed to temperature, air and surfaces.

Recovery is decided before starting.If the product allows return to the tank, it must be defined under what condition—temperature, time, filtration—and how many times.If it is not accepted, the waste is segregated and managed accordingly.What is not advisable is to improvise at the end of the batch, with the operator deciding under time pressure.The rule is written in the procedure and does not depend on the criteria of each turn.

The residual calculation helps to explain performance differences between batches and to size the circuit.A long section without drainage retains more product than a short one with purging, and this difference is repeated with each product change.King Pack can review the retained volume and propose the drainage design, and documents expected losses in writing.

What to ask the filter supplier

The filter is chosen with data, not a catalog.Before deciding, it is advisable to ask about the pore size and its tolerance, the membrane and casing material, and the compatibility with the solvents of the formulation.A nominal pore size without tolerance does not allow predicting what the filter retains.

The pressure loss with the expected flow rate, the available filter area and the behavior during stops are also important.A filter that clogs quickly requires frequent changes, and each change is an opportunity for air to enter a circuit that was already purged.The pressure loss should be measured with the product and not with water, because the viscosity changes the result.

There are questions that usually remain unanswered and should be closed in writing: whether the manufacturer has validated the filter with similar products, what integrity method is proposed, how the filter batch is documented and what retention of the active ingredient can be expected.King Pack can review the selection and propose alternatives, and confirms in writing the criteria agreed with the supplier.

Spot-on batch documentation

The batch record lists what was done and with what result.In a spot-on, it must cover mixing (addition order, stirring, temperature), filtration (filter used, differential pressure), transfer and feeding, as well as filling and dose verification.Without such data, a deviation is investigated by assumption.

The record must be contemporary.Writing down at the end of the round invites error and loses the intermediate values, which are what explain a drift.It is advisable that the format distinguish between measured data, calculated data and observation, and identify who recorded each value.An orderly record also allows it to be reviewed by someone who was not in the batch.

Traceability reaches the materials in contact: batch of filter, hoses and gaskets, which determines what was exposed to the product.This information allows an investigation to be limited to a specific batch of component instead of reviewing months of production.King Pack can review the structure of the record and propose the fields that affect filling, and documents the format in writing.

How to avoid loss of active ingredient through adsorption

Adsorption is the fixation of active ingredient on surfaces: tank walls, filter membrane, hoses, valves and joints.It is not easily seen and measured, but it reduces the available concentration and can cause the first few units of a batch to come out below the intended dose.The effect is concentrated at the start, when the surfaces still have the ability to fix.

The phenomenon depends on the surface, contact time and concentration.A circuit with a lot of wall and little volume adsorbs proportionally more than a compact one.Long stops with still product on the line favor fixation and, in some cases, subsequent release to the next batch.

The measures include reducing the surface in contact, shortening the time between mixing and filling, avoiding stops with stagnant product and verifying the concentration at the beginning and end of the batch.King Pack can review the circuit and propose materials and layouts that limit the exposed surface, and confirms each recommendation in writing.

Frequent errors

  • Investigate only the nozzle. The origin may be before.
  • Choose the filter out of habit. The pore and material affect theproduct.
  • Do not purge transfer. Air reaches filler.
  • Allow hopper to empty. Level changes dose.
  • Do not record mixture. Variability cannot be explained.
  • Ignore pressuredifferential. The filter clogs without warning.

How King Pack supports

King Pack can review the supply chain and propose the appropriate filling configuration for the product.The scope includes the definition of control points and the training of personnel.Capacities and limits are confirmed in writing for each formulation.

Frequently Asked Questions

What filter does a spot-on need? Depends on the product and particle size.It must be chosen with the filter supplier and verified with the actual product.

Can filtration reduce the active ingredient? Yes, if the pore retains active particles.It is advisable to check the concentration before and after.

Can it be filled directly from the mixture? It is possible, but the distance and level control complicate repeatability.

How ​​do you avoid air in the transfer? By purging the line and preventing the pump from sucking in air.A closed circuit also helps.

Does temperature affect the spot-on? Yes, the viscosity and stability of the emulsion.It must be controlled.

What to do if the dose varies between batches? Review the chain: mixing, filter, transfer and feeding, in that order.

Is the mixing record mandatory? It is evidence of process control and traceability.Without it, the investigation depends on memory.

How ​​is the compatibility of a joint with the spot-on checked? With a test piece of the material immersed in the real formulation during the expected contact period, with control of weight, appearance and hardness.The test is documented and repeated if the formula changes.

How ​​often is the filter changed in a spot-on? There is no single answer: it depends on the particle load and the filter area.The practical reference is the differential pressure and history of each product.

For further specification, please review prefilled syringe filling and capping series and guide to choosing a machineveterinary syringe filler.These resources help you specify samples, scope, and acceptance criteria before requesting a proposal.

Sanitary filter with inlet and outlet gauges

*Sanitary filter with differential pressure gauges.*

Conclusion

Filling aspot-on starts long before the nozzle.Mixing, filtration, transfer and feeding determine what the filler receives.Controlling the chain with defined points and records allows the dose to be explained and the cause, not the symptom, corrected.

CTA

If your spot-on has a variation in dosage or air when filling, send the process diagram and mixing data.The King Pack team can review the chain and propose controls.Request a technical review.

Continue your technical review with the product, application and package-engineering resources below.